Alaris Medical 580 Infusion Pump (Keofeed II) 6-volt battery replacement
Replacement Alaris Medical 580 Infusion Pump (Keofeed II) battery set, valve regulated safe non-spillable small 6-volt 3.2ah rechargeable batteries, they are AGM and VRLA, they can be used in portable equipment offered at low competitive price direct from warehouse
Below printed on this page you will find we have listed detailed information which should be sufficient to help you consider the decision to buy new compatible replacement battery for your Alaris Medical 580 Infusion Pump (Keofeed II), this type of battery is often seen in portable medical equipment as well as alarm systems as a emergency battery backup, they can store 3.2-amp hours of energy in the 6-volt cells and capable of deep cycling, they are of course rechargeable, very important requirements in this type of installation, they will not spill and not-hazardous so safe to be handled and for use indoors or in portable equipment, the cells are AGM and VRLA, more information about the qualities of this sort of chemistry can be found below
- Alaris Medical 580 Infusion Pump (Keofeed II) battery replacement
The battery pack that you receive from us will be almost fully charged, but you should still charge them before first use, the only time you do not need to do this is if it's going into something with its own always connected power supply and charging circuit, for example a alarm system, as this will do the job of charging for you, your charger will indicate to you when it has completed this first charge, it will probably not take very long depending on the charger, the light will generally change to indicate its ready, you might just want to fit them and use, but that would be unwise, unless being fitted in a device as stated above, missing out on charging them first may well shorten overall life expectancy
If being used in a portable device it may well take a number of charges and alternating use in your equipment for the battery to condition and be able to take a full capacity charge, this is quite normal, letting your new batteries sit in a discharged state, even partially is not a good idea, so if being used in a portable device as soon as you have used them put them back on charge, you cannot rejuvenate this kind of battery by deliberately running them down, going out of your way to fully discharge the batteries will reduce their life span, so do not do it, there may be many reasons for the equipment not be used on a regular basis, if there are protracted periods where this is the case then ensure the batteries are charged before hand and then topped up every four weeks but do not leave on a charger for more than 24-hours at a time
These 6-volt batteries are valve regulated and AGM or absorbed glass mat, not need for any liquid as the acid is held within the glass mat, this means they will not spill and not-hazardous so safe for use around the home and or portable equipment, they are deep cycle which would be required in this sort of application
The information we have provided on this page should only be used as a guide, you should carefully check before ordering as many are very similar, if still in doubt you can look at your old battery, take a note of the dimensions and anything that may be written on the side of them, this will always be the best way, we have also included the physical dimensions on this page so you can confirm, these 6-volt 3.2ah batteries are made mainly of lead which is deemed easy to be recycled, more information about recycling can be found at the foot of this page
Voltage = 6-volts
Capacity = 3.2Ah @20Hr
Chemistry = Pb, sealed lead acid, VRLA, AGM
There are 1 rechargeable batteries for the Alaris Medical 580 Infusion Pump (Keofeed II) here is the dimensions of a single battery
Length = 134mm or 5.27-inches
Width = 34mm 1.33-inches
Height = 60mm or 2.36-inches
Battery layout - from chart below = 1