Invacare Mistral powerchair battery replacement.
Replacement Invacare Mistral powerchair batteries, rechargeable valve-regulated sealed lead 12v non-spillable mobility battery, are available at a low, competitive price directly from the warehouse.
- Invacare Mistral powerchair battery
There are two batteries in this set as would be required for the Invacare Mistral.
The Invacare Mistral powerchair could come with either 31 or 51ah GEL batteries, if you wish to order the larger batteries then they can be selected above from the easy upgrade drop down menu under avaiable options above.
The batteries will be delivered with a reasonable charge, but you still need to give them a full charge before using them for the first time. The time of the first charge will depend on the charger. Just leave it on until it's finished. Do not miss out on this important first step. It will help set them up and possibly extend their overall life expectancy.
It may well take several full charges and alternating use in your equipment for the battery to condition and be able to take a full-capacity charge; this is quite normal. Ensure that after every use, you charge the batteries. Letting them sit in a partially discharged state is not wise, do not attempt to discharge the batteries fully, this can reduce life span quite drastically, so cost you money in the long run. There may be many reasons for the equipment not to be used regularly; if there are protracted periods where this is the case, then ensure the batteries are charged beforehand and then topped up every four weeks, but do not leave them on a charger for more than 24 hours at a time.
Please note you should use all the information on this page only as a guide. While we have tried here to assist you in getting the correct batteries for your mobility equipment, it should be noted that there are many very similar codes if you are not sure, you should always double-check what you have before ordering, this may also allow you to see how easy it is going to be to change the batteries, take note of the dimensions and anything written on the side of them, all the physical sizes of the batteries are listed on this page, the batteries are as you would expect recyclable, more detailed information on recycling can be found at the foot of this page.
Voltage = 12v
Capacity = 31.6Ah @20Hr
Chemistry = absorbed glass mat, AGM, VRLA
There are two batteries for use in the Invacare Mistral powerchair. The overall size of the batteries are:
Length = 195mm or 7.67-inches
Width = 130mm 5.11-inches
Height = 156mm or 6.14-inches.
If indeed you wish to purchase the 51ah GEL batteries, then the physical size of each is as follows:
Length = 228mm or 8.98-inches
Width = 139mm or 5.47-inches
Height = 205mm or 8.07-inches - including terminals = 235mm or 9.25-inches.